MindMetre Research has published the findings of an enquiry on the use of passive safety-engineered devices among NHS trusts.
The probe sought to determine whether the use of passive devices may be linked to mis-dosage or non-delivery of insulin.
And it found that a third of NHS trusts had experienced instances of mis-dosage or non-delivery of insulin to patients when passive devices were being used.
While the EU Directive on Sharps Safety mandates the use of safety devices, it does not proscribe the type of devices to be used.
Guidance from the Royal College of Nursing (RCN) notes: “Safety-engineered devices have a built-in feature to reduce the risk of a sharps injury before, during, and after use.
“Devices can be passive or active. For example, passive devices have an automatic safety mechanism that is activated after use…. An active device needs to be manually activated by the member of staff.”
Freedom of choice
However, despite the freedom of choice between active or passive delivery mechanisms that is carefully underlined in the legislation and professional association documents, recommendations for the blanket use of passive devices are widespread.
However, such blanket advice may, in some significant healthcare settings, be misleading.
In the context of diabetes administration, the authors of the research report received anecdotal evidence from diabetes specialist nurses in NHS trusts where two phenomena had taken place:
- Insulin pooling on the skin of patients after using passive injection devices, suggesting that the dose had either been under delivered or not delivered at all
- Instances of diabetics experiencing an adverse event related to misdosage while still in the unit or on trust premises
While these anecdotes were of great concern, a scan of official records indicated there was an absence of precise data around these issues.
Rethinking the guidance
MindMetre Research therefore made an enquiry to all NHS trusts in England and Wales, under the Freedom of Information Act 2000, to gain a picture of how widespread these anecdotal experiences might be.
The purpose of the enquiry was to provide some initial evidence as to whether diabetes specialist units might need to assess – or re-assess – which type of safety-engineered delivery device is most appropriate for insulin administration to diabetics attending their units.
The resulting evidence revealed:
- Over a third of trusts (36.4%) had experienced insulin pooling when using passive devices to administer insulin.
- A quarter (25%) reported they had experienced misdosage of insulin when using passive devices, evidenced by an adverse related patient event on-premises
- A handful of trusts reported that they had switched from passive to active delivery devices because of concerns over patient wellbeing and the avoidance of mis-dosage
A MindMetre spokesman said: “Our research has shown that, as with many other areas of care, a one-size-fits-all approach is rarely in the patient’s best interests.
Safety first
“It serves to underline that every drug delivery scenario needs to be assessed on its merits when evaluating the balance between patient outcomes and HCP safety – especially around device options and choices where the cost difference is not extreme.
“Safety legislation was introduced aver a decade ago to protect healthcare professionals from avoidable harm - and this is a very good thing. However, the wellbeing of patients, especially vulnerable or less dextrous patients, is always the key consideration when such choices are being made.”
The full report on this enquiry can be accessed here